Pentru persoane fizice se aplica 5% TVA
Producator: | ![]() |
Technical Data
DC input data 3.0 NX1 M2 3.7 NX1 M2
Max. recommended PV generator power 4500 W 5520 W
MPP range@rated power 140 – 480 V 165 – 480 V
Operating range 80 – 550 V 80 – 550 V
Rated DC voltage / start voltage 360 V / 100 V 360 V / 100 V
Max. no-load voltage 580 V 580 V
Max. input current 2 x 12 A 2 x 12 A
Max. short circuit current Isc max 2 x 18 A 2 x 18 A
Number of MPP tracker 2 2
Connection per tracker 1 1
Max.input power per tracker 3500 W 3500 W
AC output data
Rated active power 3 000 VA 3 680 VA
Max. apparent power 3 000 VA 3 680 VA
Line voltage 230 V (1 / N / PE) 230 V (1 / N / PE)
Voltage range (Ph-Ph) 180 – 290 V 180 – 290 V
Rated frequency (range) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz)
Rated current 13.0 A 16.0 A
Max. current 15.0 A 16.0 A
Reactive power / cos phi 0.8 overexcited – 0.8 underexcited 0.8 overexcited – 0.8 underexcited
Max. total harmonic distortion (THD) <3 % <3 %
Number of grid phases 1 1
General data
Max. efficiency 97.5 % 97.5 %
Europ. efficiency 96.9 % 97.0%
Standby consumption <5 W <5 W
Circuitry topology transformerless transformerless
Mechanical data
Display LEDs + APP LEDs + APP
Communication Interface WiFi WiFi
DC connection DC plugs (SUNCLIX) DC plugs (SUNCLIX)
AC connection plug-in connector plug-in connector
Ambient temperature -25 °C – +60 °C -25 °C – +60 °C
Humidity 0 – 100 % 0 – 100 %
Max. installation elevation (above 3 000 m 3 000 m
Min. distance from coast 2 000 m 2 000 m
Cooling convection cooling convection cooling
Protection class IP65 IP65
Noise emission < 25 db (A) < 25 db (A)
H x W x D 376 x 355 x 145 mm 376 x 355 x 145 mm
Weight 11 kg 11 kg
Certifications
Safety IEC 62109-1 / -2, EN 61000-6-1 / -2 / -3/-4, EN 61000-3-2 / -3 / -11 / -12, EN50549-1,
VFR 2019 & UTE C15-712-1, CEI 0-21, C10/C11, IEC61727, IEC62116, IEC61683
Grid connection rule overview see homepage / download area
Technical Data
DC input data 3.0 NX1 M2 3.7 NX1 M2
Max. recommended PV generator power 4500 W 5520 W
MPP range@rated power 140 – 480 V 165 – 480 V
Operating range 80 – 550 V 80 – 550 V
Rated DC voltage / start voltage 360 V / 100 V 360 V / 100 V
Max. no-load voltage 580 V 580 V
Max. input current 2 x 12 A 2 x 12 A
Max. short circuit current Isc max 2 x 18 A 2 x 18 A
Number of MPP tracker 2 2
Connection per tracker 1 1
Max.input power per tracker 3500 W 3500 W
AC output data
Rated active power 3 000 VA 3 680 VA
Max. apparent power 3 000 VA 3 680 VA
Line voltage 230 V (1 / N / PE) 230 V (1 / N / PE)
Voltage range (Ph-Ph) 180 – 290 V 180 – 290 V
Rated frequency (range) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz)
Rated current 13.0 A 16.0 A
Max. current 15.0 A 16.0 A
Reactive power / cos phi 0.8 overexcited – 0.8 underexcited 0.8 overexcited – 0.8 underexcited
Max. total harmonic distortion (THD) <3 % <3 %
Number of grid phases 1 1
General data
Max. efficiency 97.5 % 97.5 %
Europ. efficiency 96.9 % 97.0%
Standby consumption <5 W <5 W
Circuitry topology transformerless transformerless
Mechanical data
Display LEDs + APP LEDs + APP
Communication Interface WiFi WiFi
DC connection DC plugs (SUNCLIX) DC plugs (SUNCLIX)
AC connection plug-in connector plug-in connector
Ambient temperature -25 °C – +60 °C -25 °C – +60 °C
Humidity 0 – 100 % 0 – 100 %
Max. installation elevation (above 3 000 m 3 000 m
Min. distance from coast 2 000 m 2 000 m
Cooling convection cooling convection cooling
Protection class IP65 IP65
Noise emission < 25 db (A) < 25 db (A)
H x W x D 376 x 355 x 145 mm 376 x 355 x 145 mm
Weight 11 kg 11 kg
Certifications
Safety IEC 62109-1 / -2, EN 61000-6-1 / -2 / -3/-4, EN 61000-3-2 / -3 / -11 / -12, EN50549-1,
VFR 2019 & UTE C15-712-1, CEI 0-21, C10/C11, IEC61727, IEC62116, IEC61683
Grid connection rule overview see homepage / download area
Technical Data
DC input data 4.0 NX1 M2 5.0 NX1 M2
Max. recommended PV generator power 6000 W 7500 W
MPP range@rated power 180 – 480 V 220 – 480 V
Operating range 80 – 550 V 80 – 550 V
Rated DC voltage / start voltage 360 V / 100 V 360 V / 100 V
Max. no-load voltage 580 V 580 V
Max. input current 2 x 12 A 2 x 12 A
Max. short circuit current Isc max 2 x 18 A 2 x 18 A
Number of MPP tracker 2 2
Connection per tracker 1 1
Max.input power per tracker 3500 W 3500 W
AC output data
Rated active power 4 000 VA 5 000 VA
Max. apparent power 4 000 VA 5 000 VA
Line voltage 230 V (1 / N / PE) 230 V (1 / N / PE)
Voltage range (Ph-Ph) 180 – 290 V 180 – 290 V
Rated frequency (range) 50 Hz / 60 Hz (45 – 65 Hz) 50 Hz / 60 Hz (45 – 65 Hz)
Rated current 17.4 A 21.7 A
Max. current 20.0 A 22.7 A
Reactive power / cos phi 0.8 overexcited – 0.8 underexcited 0.8 overexcited – 0.8 underexcited
Max. total harmonic distortion (THD) <3 % <3 %
Number of grid phases 1 1
General data
Max. efficiency 97.5 % 97.5 %
Europ. efficiency 97.0 % 97.0%
Standby consumption <5 W <5 W
Circuitry topology transformerless transformerless
Mechanical data
Display LEDs + APP LEDs + APP
Communication Interface WiFi WiFi
DC connection DC plugs (SUNCLIX) DC plugs (SUNCLIX)
AC connection plug-in connector Plug-in Connector
Ambient temperature -25 °C – +60 °C -25 °C – +60 °C
Humidity 0 – 100 % 0 – 100 %
Max. installation elevation (above 3 000 m 3 000 m
Min. distance from coast 2 000 m 2 000 m
Cooling convection cooling convection cooling
Protection class IP65 IP65
Noise emission < 25 db (A) < 25 db (A)
H x W x D 376 x 355 x 145 mm 376 x 355 x 145 mm
Weight 11 kg 11 kg
Certifications
Safety IEC 62109-1 / -2, EN 61000-6-1 / -2 / -3/-4, EN 61000-3-2 / -3 / -11 / -12, EN50549-1,
VFR 2019 & UTE C15-712-1, CEI 0-21, C10/C11, IEC61727, IEC62116, IEC61683
Grid connection rule overview see homepage / download are